Explosion-proof variable speed actuators SAVEx and SARVEx

Multi-turn actuators SAVEx .2 for open-close duty and SARVEx .2 for modulating duty are paired with intelligent ACVExC 01.2 actuator controls. The proven AUMA SAEx/SAREx range is enhanced by variable speed models. With a wide speed control ratio of 1:10, AUMA is spearheading market technology in providing variable speed actuators for use in potentially explosive atmospheres.

 
SAVEx multi-turn actuators are rated for open-close duty and positioning duty (classes A and B) / (short-time duty S2 - 15 min)Special sizing for longer running times is available for the S2 - 30 min duty.
 
SARVEx multi-turn actuators are rated for modulating duty (class C) S4 - 25 %. Special versions for S4 - 50 % are also available.

Product Features

Design features SAVEx:

  • Torque range from 10 Nm to 1,000 Nm.
  • Output speeds from 6 to 216 rpm.
  • Limit and torque sensing.
  • Available with 3-ph AC.
  • Handwheel for manual operation.
  • Valve protection by soft start and stop.
  • Avoiding pressure surge by speed profile.
  • EMERGENCY behaviour and failure behaviour with separate speed setpoints.
  • Synchronous link – synchronous operation of two actuators.

Design features SARVEx:

  • Torque range from 15 Nm to 1,000 Nm.
  • Modulating torque range from 15 Nm to 350 Nm.
  • Max. number of starts 1,500 c/h.
  • Output speeds from 6 to 216 rpm.
  • Limit and torque sensing.
  • Available with 3-ph AC.
  • Handwheel for manual operation.
  • Superior positioning accuracy.
  • Valve protection by soft start and stop.
  • Avoiding pressure surge by speed profile.
  • EMERGENCY behaviour and failure behaviour with separate speed setpoints.
  • Synchronous link – synchronous operation of two actuators.

Ambient conditions:

  • High enclosure protection.
  • High quality corrosion protection.
  • Wide ambient temperature ranges.

Options:

  • Intermediate position switches.
  • Switches in tandem version.
  • Remote position transmitter.
  • Magnetic limit and torque Transmitter.
  • Mechanical position indicator.

Interfaces:

  • Electrical connection via AUMA plug/socket connector (optionally terminals).
  • Cable entries in different versions.
  • Output drive types according to ISO and DIN Standards.

Interface and functional features:

  • Programmable potential-free output contacts for status signalisation.
  • Valve protection by soft start and stop.
  • Avoiding pressure surges thanks to speed profile.
  • EMERGENCY behaviour and failure behaviour with separate speed setpoints.
  • Multiport valves with up to 16 ports are positioned both quickly and with utmost precision.
  • Process controller (PID).
  • Fieldbus control .
  • EMERGENCY behaviour in and behaviour on loss of communication (programmable) .
  • Operating data logging .
  • Bluetooth interface to notebook and Android tablet .

Approvals:

  • Europe - ATEX
    II2G Ex d(e) IIC T4 or T3 Gb
    II2G c IIC T4 or T3
    II2D Ex tb IIC T130 °C or T190 °C Db IP6x
  • International level/Australia - IEC
    II2G Ex d(e) IIC T4 or T3 Gb
    II2G c IIC T4 or T3
    II2D Ex tb IIC T130 °C or T190 °C Db IP6x